CLAMP ON FOR BURIED PIPES
Permanently installed clamp-on ultrasonic flow measurement system for buried water and waste water pipes
Fluxus WD Series
Highly accurate non-invasive flow measurement irrespective of the flow direction (bidirectional), with outstanding measurement dynamics, excellent zero-point stability and high repeatability of the measurement results
• Submersible ultrasonic transducers (IP68), additionally protected by the very robust transducer mounting fixture made of stainless steel (316Ti) Variofix C, provide a reliable and durable solution for flow measurement on buried pipes or for applications where the measuring point can be overflowed
• Simple retrofitting on existing water networks without interruption of supply and disposal and without the need for shaft construction and pipe intrusion, thus saving time and cost
- Very low installation costs and zero pipe interference
- Extremely accurate down to flow velocities as low as 0.01 m/s
- No zero calibration needed and permanently drift-free
- Permanent coupling pads
- IP68 transducers
- Transducers can be permanently buried (no chamber required)
- Drift-free measurements
- Reliable and accurate data
- Low installation costs
- Built to last
- Works on difficult pipes
FLUXUS WD100 & WD200
Flow measurement for fresh water pipes 80-120mm
The WD100 & 200 are the ideal ultrasonic liquid flow meters for permanent installation in pits and in the field.
The transmitter has a Stainless Steel housing and can be operated through the glass fascia by a magnet pen without opening the housing. It is IECEx certified for use in Zone 1.
The FLUXUS G801 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, by using the rugged stainless steel VARIOFIX C mounting rail, the system does not suffer from wear, tear or clogging. Furthermore, it will not cause any pressure drops inside the pipe and there is no risk of leaks.
The gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C.
With up to two measurement channels, the FLUXUS G801 permanent gas flow meter can also be applied to difficult measurement points, is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
FLUXUS WD 400
Permanent clamp-on flowmeter for buried pipes 50…460mm
The FLUXUS G608 portable gas flowmeter and the FLUXUS F608 portable liquid flowmeter have been specifically engineered for use within hazardous areas, IECEx Zone 2.
It is the ideal portable flowmetering solution for liquids or gas whether for a temporary replacement of a stationary flow meter, check metering or service operation. Its internal data logger can store up to 100, 000 data points with the measurement data available for download and presentation by user friendly software.
The G608/F608 portable flow meter can be battery operated for typically up to 14 hrs before re-charge.
The G608/F608 portable flow meter goes where other portable devices can’t.
FLUXUS WD 1200 & 6500
Permanent clamp-on flowmeter for buried pipes 100…1250 & 400…6600mm
The FLUXUS WD1200 and 6500 permanent liquid flowmeter have been engineered for use in the water industry and are especially useful for buried pipe applications.
It is the ideal portable flowmetering solution for liquids or gas whether for a temporary replacement of a stationary flow meter, check metering or service operation. Its internal data logger can store up to 100, 000 data points with the measurement data available for download and presentation by user friendly software.
The G608/F608 portable flow meter can be battery operated for typically up to 14 hrs before re-charge.
The G608/F608 portable flow meter goes where other portable devices can’t.